Dimension Table (mm)

Model A B C D E F H L x R
ABF-15 530 450 495 415 550 450 500 230 x 210
ABF-20 580 550 545 515 650 500 550 260 x 230
ABF-25 600 550 565 515 650 520 550 300 x 260
ABF-30 700 700 665 565 700 620 600 330 x 300
ABF-40 840 700 805 565 700 760 600 360 x 310
ABF-50 940 800 905 765 900 860 800 375 x 375
ABF-60 980 900 955 865 1000 900 900 450 x 400

Performance Parameter

Model Unit ABF-15 ABF-20 ABF-25 ABF-30 ABF-40 ABF-50 ABF-60
Voltage (V/HZ) 220/50 220/50 220/50 220/50 380/50 380/50 380/50
Rated Power (W) 200 300 450 550 800 1000 1500
Airflow (m3/h) 1500 2000 2500 3000 4000 5000 6000
Static Pressure (Pa) 200 220 250 250 300 300 350
Noise (dB(A)) 52 55 57 58 60 62 63
Weight (Kg) 24 30 33 35 47 78 85
Duct Size (mm) 230 x 210 260 x 230 300 x 260 330 x 300 360 x 310 375 x 375 450 x 400
Machine Size (mm) 450x450x500 550x500x550 550x520x550 700x620x600 700x760x600 800x860x800 900x900x900

DIMENSION DIAGRAM

OUTDOOR HAZE AIR IS NOT SAFE, NEITHER INDOOR

Common Ventilation Issues for

Homes and Light Commercial Buildings

The HRV unit brings a continuous supply of fresh air into a home while exhausting an equal amount of contaminated air. During winter, fresh incoming air is tempered by the heat that is transferred from the outgoing air so you save on energy costs, while during summer, the incoming air is pre-cooled if the house is equipped with an air cooling system.

Supply Only Fan Application

Postive Air Pressure

Forces hot and/or humid air into walls and insulation.

   

Exhaust Only Fan Application

Negative Air Pressure

The unfiltered air increases risks of mold and causes energy costs to be higher.

Energy saving principle

Heat recovery calculating equation
SA temp. = (RA temp. -IA temp.) Xtemp. recovery efficiency + OA temp. Example: 14.8°C = (20°C-0°C) x 74% + 0°C
Heat recovery calculating equation
SA temp. = IA tmep.-(IA temp. -RA temp.) Xtemp. recovery efficiency Example: 27.8t = 33°C-(33°C-26°C) x 74%

Why You’ll Love owning our Heat Recovery Ventilator

  • Indoor air is fresh, comfortable and healthy
  • Allergy & asthma triggers are removed
  • Room-to-room climates are more consistent
  • Dust less often
  • Helps control pet odors
  • You’ II feel better – even sleep better
  • Your home will be safer from mold and mildew
  • Pet and cooking odors are cleared quickly
  • Maintenance is easy – system even alerts when it’ s time for a filter change
  • The service life of your HVAC system is extended
  • Quiet operation
  • Best product support available

User Reviews

0.0 out of 5
0
0
0
0
0
Write a review

There are no reviews yet.

Be the first to review “FAN BOX”

Your email address will not be published. Required fields are marked *

No more offers for this product!

General Inquiries

There are no inquiries yet.

Econaur
Logo
Compare items
  • Total (0)
Compare
0
Shopping cart